-40%

US Dental Endodontic Gutta Percha Obturation Endo Heated Pen /Tooth gum Cutter

$ 11.61

Availability: 48 in stock

Description

Ship from USA to USA
Model:Op-fill can be heat to 200 º C in 3s, can be melting all kinds of Gutta percha.It support the vertical compaction of Gutta percha for the root canal filling. It is intended exclusively for use by trained dentiet only in clinic or laboratory.
Safety caution:
The temperature of tip is very high during the surgery , in order to prevent from being burned, please avoid it directly contact to the soft tissue.
Specification:
Charging system
Operating Voltage DC.3.6V
Adaptor Input: AC 100V/220V 50-60HZ
Power: 10w
Charging time 4 hours
Packing size: 165*125*38mm
Usage:
Heat: Press the button to heat the tip, the Led indicator light red.The tip can reach working temperature within 3 second.
Charge:Put the obturation pen onto the charging base, the LED indicator light blue.The unit should be continuous charging more than 8 hours from low voltage to full charge.
Package includes:
Charging Base-----1 PC
Obturation Pen-----1 PC
Pen Tip -----2PCS
NEW Dental
A-BLADE Ⅱ
Gutta Percha /Tooth gum Cutter with 4 tips
Feature

1. Design ingenious , Shape beautiful , Conform to the human body engineering
2. Wireless mode , Operation ,flexible, convenient
3. Rapid heating , highest temperature of 260º C
4. High-capacity can be charged Nickel cadmium battery, charging time 3 hours
5. Fever needle can be sterilized by high temperature and high pressure , repeated use.
Technical Paraments
:
1. Charger voltage: AC1
1
0
V or
2
2
0V
50/60HZ
2. Battery: 1.2V 2400mAh
3. Power2.5W
4. Weight: about 305g
Packing List:
1x main unit
4x tips
1x Box
1x English manual
Charging

1
.
First,charge the instrument by connecting the charging station to a mains power socket
2
.
Plug the handipece into the socket in the charging station . While the instrument is charging,the LED lights up on the handpiece.
Use
:
Fit a cutting tip onto the handpiece.Make sure that the angle of the tip is pointing in the opposite direction to the operating button,This makes work easier.
Important
:
Never bend the tip while it is still in the handpiece.
1
.
Insert the cutting tip into the cavity while it is cold (without pressing the operating button).The gutta-percha point to be cut off must be encircled by the loop of the cutting tip.
2
.
As soon as the cutting tip is located directly on the canal access,press the operating button.
3
.
The tip heats up in seconds and the gutta-percha point can be quickly and cleanly removed.
4
.
After the point has been cut off ,release the operating button. The cutting tip immediately cools down and can be removed from the patient's mouth .The operating button is a “contact button” which only switches the button is released,the instrument switches off.
5
.
Remove the cutting tip from the handpiece after use.
Attention
:
Please don't continue to press the button more than 30 seconds.
FDA Statement
The sale of this item may be subject to regulation by the U.S. Food and Drug Administration and state and local regulatory agencies. If so, you can bid on this item only if you are an authorized purchaser. If the item is subject to FDA regulation, I will verify your status as an authorized purchaser of this item before shipping of the item.
Seller name:dr.baistra
City,State:SHENZHEN,China
Telephone number:0755-32870423